| Coil Data (20℃) | ||||||||||
| Coil Voltage | Coil Resistance (Ω) | Coil Power (W) | Operating Voltage | Releasing Voltage | Allowing Voltage | Pulse Duration | ||||
| (VDC) | Single Double | Single Double | (VDC) | (VDC) | (VDC) | (ms) | ||||
| 6 | 16 | 8/8 | 2.25 | 4.50 | ≤4.2 | ≤4.2 | 9 | ≥90 | ||
| 9 | 36 | 18/18 | ≤6.3 | ≤6.3 | 13.5 | |||||
| 12 | 64 | 32/32 | ≤8.4 | ≤8.4 | 18 | |||||
| 24 | 256 | 128/128 | ≤16.8 | ≤16.8 | 36 | |||||
| Coil Voltage | Coil Resistance (Ω) | Coil Power (W) | Operating Voltage | Releasing Voltage | Allowing Voltage | Pulse Duration | ||||
| (VDC) | Single Double | Single Double | (VDC) | (VDC) | (VDC) | (ms) | ||||
| 6 | 12 | 6/6 | 3.00 | 6.00 | ≤4.2 | ≤4.2 | 9 | ≥90 | ||
| 9 | 27 | 13.5/13.5 | ≤6.3 | ≤6.3 | 13.5 | |||||
| 12 | 48 | 24/24 | ≤8.4 | ≤8.4 | 18 | |||||
| 24 | 192 | 96/96 | ≤16.8 | ≤16.8 | 36 | |||||
| Contact Data | Characteristics | |||||||||
| Contact Form | 1B/1H(two contacts) | Operate Time | 30ms Max. | |||||||
| Contact Material | AgSnO2 | Release Time | 30ms Max. | |||||||
| Contact Resistance | Max.1.0mΩ (1A 6VDC) | Insulation Resistance (500VDC) | 500MΩ Min. | |||||||
| Dielectric Strength (50/60Hz,1Min) | Contact to Coil | 4000VAC | ||||||||
| Rated Load(Resistive) | 120A 250VAC | Across Open Contacts | 2000VAC | |||||||
| Max.Switching Voltage | 250VAC | Contact to contact | ||||||||
| Max.Switching Current | 120A | Surge Voltage (1.2/50μs) | Contact to Coil | 20KVAC | ||||||
| Max.Switching Power | 30000VA | |||||||||
| Service Life | Mechnical Endurance | 2×106OPS | Dielectric Creepage | 8mm | ||||||
| Electrical Endurance | 6×103OPS | Unit Weight | About 70g | |||||||
| Max.Short-Circut Current | 3000A/10ms 6000A/10ms(no explosion) | Outline Dimension (without connecting parts) | 42X32X20.8 (mm) | |||||||
| Environmental Data | ||||||||||
| Ambient Temperature | -40℃~+85℃ | Relative Humidity | 5%-85% RH | |||||||
| Vibration | 10-55Hz 1.5mm | Shock | 98m/s2 | |||||||