Add to Cart
Single phase current transformer Blue case CT DC component Max current 120A
Suitable for high precision, small phase error requirments of three-phase electric energy meters
More space in the meter can be saved with combined current transformer
Linear output current, high precision
Encapsulated with epoxy resion,with high insulation ability
It accords with IEC60044-1 0.05 class, 0.1 class, 0.2 class
Rated primary current | Max primary current | Rated secondary current | Turn ratio | Accuracy class | DC component | Shileding | Load resistance |
I p(A) | I max(A) | I s(mA) | N | (%) | (%) | (T) | Rb |
5 | 60 | 2 | 1:2500 | 0.05/0.1/0.2 | ±3% | unavailable | 5Ω,10Ω,20Ω |
5 | 60 | 2.5 | 1:2000 | 0.05/0.1/0.2 | |||
10 | 60 | 4 | 1:2500 | 0.05/0.1/0.2 | ±3% | ||
10 | 60 | 5 | 1:2000 | 0.05/0.1/0.2 | |||
10 | 60 | 10 | 1:1000 | 0.1/0.2 | |||
5 | 80 | 2 | 1:2500 | 0.1/0.2 | ±3% | ||
10 | 100 | 4 | 1:2500 | 0.1/0.2 | ±3% | ||
20 | 100 | 8 | 1:2500 | 0.1/0.2 | ±3% | ||
20 | 100 | 10 | 1:2000 | 0.1/0.2 | |||
20 | 100 | 20 | 1:1000 | 0.1/0.2 | |||
Working temperature | −40℃~ 85℃ | ||||||
Isolation voltage | 4000Vrms, 1 Min, No breakdown, No arcing | ||||||
Insulation resistance | ≥1000MΩ | ||||||
Operating temperature | 50Hz~60Hz |